+370 661-08345Ships to the EU
All prices excl. VATHelpTrack inquiry
624.103.119
Kromschroder

Kromschroeder 88600047 BCU370WI1FEU0D1 burner control unit

SKU 624.103.119On request
€1,064.44excl. VAT
Request a price
Ships to the EU

Kromschroeder 88600047 BCU370WI1FEU0D1 gas burner safety control box controls, ignites and monitors industrial forced draught burners of unlimited capacity in intermittent or continuous operation. Kromschroder BCU370WI1FEU0D1 88600047 gas burner control unit technical data Mains voltage: 230 V AC,  50/60 Hz Flame control with UV sensor or ionisation sensor Flame signal for Ionization control: 1 – 28 μA, UV control: 1 – 35 μA For intermittent or continuous operation Air pressure check during pre-purge and operation by external air pressure switch DL Maximum length of ignition cable with integrated electronic ignition: 1 m Maximum length of ionisation/UV cable: 50 m (164 ft) Max. number of operating cycles: 250,000 Ambient temperature: -20 - +60 °C (-4 – +140 °F) Enclosure: IP 54 pursuant to IEC 529 Housing made of impact-resistant and heat-resistant plastic. Plug-in upper section with operating and display elements. Lower section with connection terminals, earthing strip and pre-wired neutral bus with spacious wiring chamber Electronic ignition, single-pole Fan control: 3 A relay Valve control: three-point step Flame control: ionization control (continuous or intermittent operation) or UV control (intermittent operation with UVS) Digital input function: DGmax. Monitoring With bottom section Minimum burner pause time tBP: 0 s Burner start-up attempts: 1 Switch-on delay time tE: 0 s Pre-ignition time tVZ: 1 s Safety time 1, burner/pilot burner start-up tSA1: 5 s Flame proving period 1, burner/pilot tFS1: 2 s Safety time 2, main burner start-up tSA2: 3 s Flame proving period 2, main burner tFS2: 2 s Controller enable signal delay time tRF: 0 s Minimum burner on time tB: 0 s Safety time during operation tSB: 1 s V2 during burner operation: Off Behaviour in the event of flame failure during operation: fault lock-out Burner switch-off threshold: 1 micro A UVS check (1 x in 24 hours): Off Operating time in Manual mode: limited to 5 minutes User-defined password Air monitoring during pre-purge: On Air monitoring during operation: On Gas pressure monitoring: On Digital input function: DGmax. Monitoring Fan run-up time tGV: 0 s Valve control: On Pre-purge on each start-up: On Pre-purge time tPV: 30 s Post-purge time tPN: 0 s Weight: 1.8 kg Krom schroder BCU370WI1FEU0D1 88600047 gas burner control unit application Krom schroder 88600047 BCU370WI1FEU0D1 control box works for both directly ignited forced draught burners and those with pilot burners. It activates the fan and positions the butterfly valve for pre-purge and ignition. After burner startup, it signals an external controller for valve adjustment as needed. Post-purge follows burner shutdown. Kromschroder 88600047 BCU370WI1FEU0D1 gas burner control box monitors gas and air pressure, with an optional tightness control function for valve monitoring. Programming via optical interface and BCSoft software ensures precise adaptation. Adjustable start-up attempts and automatic restart enhance flexibility. Quick-start allows compliant burner startup without pre-purge, ensuring rapid heat output upon demand.

Codes & cross-references

2
Article624.103.119
SKU88600047