Electrode Ecoflam 65322159
Ecoflam ionization electrode 180 mm, 65322159. Original flame sensor for safe operation of Ecoflam burners. Ecoflam ionization electrode 65322159 (E605/1) is an original safety component for Ecoflam gas and oil burners. The product is designed for continuous monitoring of flame presence in the combustion chamber and transmitting the ionization signal to the combustion control automation. If your burner starts but shuts down in alarm mode after a few seconds, the cause is often a malfunction of this element. Specifications: Parameter Value; Part numbers 65322159, E605/1, BFE01013/2, 400010089800, 390.946.136; Manufacturer Ecoflam (Italy); Electrode type Ionization (flame control); Total length 180-199 mm (varies by batch); Rod diameter Ø2.6-3 mm; Rod length 70-90 mm; Ceramic insulation diameter Ø8 mm; Ceramic insulation length 100 mm; Connection type Plug Ø4 mm; Fixation Fixed; Compatibility The electrode is suitable for Ecoflam gas burners. Similar manufacturer part numbers: BFE01031/2, 65320852, 65321624, 65074043. Key advantages: Original Ecoflam component: Full compliance with factory specifications ensures compatibility and reliable operation in Ecoflam burners. Real-time flame control: The ionization electrode is a critical element of the heating system safety. It continuously monitors the presence of a flame in the combustion chamber. If absent, the automation immediately stops fuel supply, preventing an emergency related to gas leakage. Extended length 180-199 mm for deep combustion chambers: This electrode has a total length of up to 199 mm (ceramic part 100 mm, rod 70-90 mm). This is the optimal size for installation in burners with deep chambers.