+971 50 990 9659Wysyłka do UE i na Bliski Wschód
Wszystkie ceny bez VATPomocŚledź zapytanie
KROM
Moduł sterujący palnika Kromschroeder BCU460W3P2C0D0000K1E0-/LM400WF0O0E1 (88680262)
Kromschroder

Moduł sterujący palnika Kromschroeder BCU460W3P2C0D0000K1E0-/LM400WF0O0E1 (88680262)

SKU 624.103.159Na zamówienie
Zapytaj o cenę
Wysyłka do UE i na Bliski Wschód

Kromschroder BCU460W3P2C0D0000K1E0-/LM400WF0O0E1- 88680262 automatic gas firing device control, ignite and monitor gas burners for intermittent or continuous operation. As a result of their fully electronic design, they react quickly to various process requirements and are therefore suitable for frequent cycling operation. Krom schroder BCU460W3P2C0D0000K1E0-/LM400WF0O0E1- 88680262 control unit technical data: For grounded and ungrounded mains Inherent consumption: approx. 9 VA plus inherent consumption of the integrated ignition transformer Signal and control line: max. 2.5 mm2 Cable for burner ground/PE wire: 4 mm2 Is supplied for two cable glands with one seal insert each for cable diameters between 7 and 12 mm Flame control with UV detector or ionization sensor Flame signal for ionization control: 1 – 28 μA, UV control: 1 – 35 μA For intermittent or continuous operation Maximum length of ignition cable with integrated electronic ignition: 5 m Maximum length of ionization/UV cable: 50 m Ambient temperature: -20 to +60°C, no condensation permitted Enclosure: IP 54 pursuant to IEC 529 Weight: 5.1 kg Standard version Mains voltage: 230 V AC, 50/60 Hz Ignition transformer: 8 kV, 20 mA, ED 100 % Flange plate: M32 Valve proving system: none High temperature operation: none Input function: none Pressure switch: none Connection plugs with screw terminals Individual packaging Energy supply: via safety interlocks Power module Series 400 Mains voltage: 230 V AC, 50/60 Hz Air actuator: none Optional output: none Energy supply: via L1 Flame control: ionization Function of contact 80, 81/82: fault signal Function of contact 95/96: burner 1 operating signal Function of contact 95/97: burner 1 operating signal Function of terminal 1: start 1 Function of terminal 2: reset Function of terminal 35: safety interlocks Switch-off threshold, burner 1: 2 micro A Flame simulation check in standby position Burner 1 start-up attempts: 3 Pre-ignition time tVZ: 0 s 1st safety time on start-up: 3 s Flame proving period 1 tFS1: 0 s Burner application: burner 1 Function of V5: Off Restart: no Combustion mode: Flame mode Over-run: Off Over-run time: 0 s Safety time during operation: 1 s Minimum burner on time tB: 3 s Minimum pause time tMP: 0 s Operating time in Manual mode limited to 5 min. Purge (bus): Of Fieldbus communication: Off Kromschroder Safety Link: Off

Numery i zamienniki

3
Article624.103.159
SKU88680262
Ref88680262, 624.103.159