Amplificatore UV per turbina a gas Honeywell EG1033AC01
Industrial power generation gas turbine installations demand the superior protection provided by Honeywell EG1033AC01 UV cell. Honeywell EG1033AC01 photo resistor detects the ultraviolet radiation emitted by a hydrocarbon flame and produces an output signal to indicate a flame or no- flame condition. Honeywell EG1033AC01 photo unit has delivered proven performance on General Electric (and GE licensee) gas turbines for more than 35 years. Land-based and off-shore applications include power generation, pumping stations, ship- board power generation among other industrial uses. A variety of sensor types, amplifier types and sensor cable lengths are available. Honeywell EG1033AC01 flame detector technical data: Physical Dimensions: 6.62 x 4.25 x 4.44 inches Mounting Holes: Four .20 in diameter holes, 6.00 x 2.00 inches apart Power Input: 20 to 35 Vdc, 10 watts max Amplifier Output: Relay Contacts Flame Detect Time: Typical 0.1 sec; max 1.0 sec Flame Loss Detect Time: 0.2 sec max