+370 661-08345Spedizione in UE
Tutti i prezzi IVA esclusaAssistenzaSegui la richiesta
KROM
Honeywell DKG972-N mod. 10 0432010 centralina di controllo
Honeywell

Honeywell DKG972-N mod. 10 0432010 centralina di controllo

SKU 534.412.084Su richiesta
115,30 €IVA esclusa
Richiedi il prezzo
Spedizione in UE

Satronic DKG972-N mod.10 0432010 gas control unit control and control two-stage atmospheric burners. Honeywell DKG972-N mod.10 0432010 gas burner control unit technical data: Operating voltage: 230 V (-15...+10%) Serial fuse: 10 A fast, 6 A slow Consumption: 12 VA Min. required ionization current (flame level): 1 mkA Sensitivity, operating mode (no flame level): 0.7 µA Sensitivity to ambient light: 0.4 µA Max. Ionization current: 26 µA Probe isolation: Probe – Ground more than 50 M Parasitic capacity: Probe – Ground less than 1000 pF Weight: 175 g Protection class: IP 40 Ice formation, water exposure and condensation: not allowed Tested in accordance with the European standard: EN 298:2003, as well as all related regulations and directives Classification EN298: ATLLXN

Codici ed equivalenze

3
Article534.412.084
SKU0432010
Ref0432010, 534.412.084