Trasformatore di accensione Brahma 15060001 T11/A
Ignition transformers BRAHMA T11/A 15060001 are suitable for liquid or gaseous fuel burners. Peculiarities - Various connection and fastening systems; - High discharge power (they are especially suitable for all those applications where long ignition wires are required); - High efficiency and ignition power. Technical data - Supply voltage: 220 V - 50 Hz - Operating temperature range: -10°C +35°C - Insulation: polyester resin - Recommended distance between electrodes: 3 - 5 mm - Standard power cable length: 550 mm - Number of poles: 1 - Output peak voltage (KV): 1 x 15 - Output effective voltage (KV): 1 x 9 - Output effective current (mA): 20 - Input effective current (A): 1.1 - Duty cycle: 33% in 3 minutes - Power consumption (VA): 240 - Weight (kg): 2 - Dust and moisture protection class: IP 00 - Ignition cable connectors: plug Ø6.3 mm - Dimensions:15x10.1x10 cm Design The magnetic core on the spark transformer BRAHMA T11/A 15060001 has the shape of a shell. The secondary windings are centrally grounded. The BRAHMA T11/A 15060001 transformer with ignition cable is equipped with a radio interference suppression shield, which must be connected to a reliable ground to be effective. Two caps, painted with fire-retardant paint, cover the coils and form a single unit with the magnetic circuit. Each transformer is identified by a fixed letter T (transformer), a series of numbers designating the model, and possibly a letter of the alphabet that identifies the specific mounting system. If the fastening system used is a standard fastening system, the corresponding advisory letter is not inserted into the part reference. For example, part designation T11 refers to a transformer with a standard mounting system, while part designation T11/N corresponds to a transformer T11 with a different mounting system. Ignition units BRAHMA T11/A 15060001 may have the same electrical characteristics, but different mounting systems, or vice versa. Compound The high voltage insulators used in the BRAHMA T11/A 15060001 transformers are of two different types, depending on how the connection to the high voltage cables is made using a screw, a 4mm diameter cylindrical terminal or a 6.3mm diameter cylindrical terminal. Unless expressly stated, a screw terminal is used as the connection terminal. The insulators are made of 30% PBT glass fiber. Installation - Carefully! Dangerous voltage may be present. - Connect and disconnect the ignition transformer only after disconnecting the power source. - Comply with applicable national and European standards (eg EN 60335-1 / EN 60335-2-102) regarding electrical safety. - Make sure that the transformer ground and the electrical system ground are well connected. - Locate a single grounding center, thereby preventing the formation of ring paths of grounding conductors. - The device can be installed in any position. - Reduce the length of the ignition cable to a minimum (this reduces parasitic capacitance and the likelihood that the ignition cable will act as an antenna transmitting interference to nearby cables). - Route the ignition cables along a separate path close to the ground planes (this reduces the influence of interference on other electrical wires). - Avoid placing high voltage cables near other cables. - Make sure that the degree of protection is appropriate for the system.