Kromschroeder 88600373 BCU370WI1FEU0D3B1-3 burner control unit
Kromschroeder 88600373 BCU370WI1FEU0D3B1-3 gas burner safety control box controls, ignites and monitors industrial forced draught burners of unlimited capacity in intermittent or continuous operation. Kromschroder BCU370WI1FEU0D3B1-3 88600373 gas burner control unit technical data Mains voltage: 230 V AC, 50/60 Hz Flame control with UV sensor or ionisation sensor Flame signal for Ionization control: 1 – 28 μA, UV control: 1 – 35 μA For intermittent or continuous operation Air pressure check during pre-purge and operation by external air pressure switch DL Maximum length of ignition cable with integrated electronic ignition: 1 m Maximum length of ionisation/UV cable: 50 m (164 ft) Max. number of operating cycles: 250,000 Ambient temperature: -20 - +60 °C (-4 – +140 °F) Enclosure: IP 54 pursuant to IEC 529 Housing made of impact-resistant and heat-resistant plastic. Plug-in upper section with operating and display elements. Lower section with connection terminals, earthing strip and pre-wired neutral bus with spacious wiring chamber Electronic ignition, single-pole Fan control: 3 A relay Valve control: three-point step Flame control: ionization control (continuous or intermittent operation) or UV control intermittent operation with UVS) Digital input function: integrated tightness control Fieldbus interface: PROFIBUS DP Bus control: three-point step With bottom section Minimum burner pause time tBP: 0 s Burner start-up attempts: 1 Switch-on delay time tE: 0 s Pre-ignition time tVZ: 1 s Safety time 1, burner/pilot burner start-up tSA1: 5 s Flame proving period 1, burner/pilot tFS1: 2 s Safety time 2, main burner start-up tSA2: 0 s Flame proving period 2, main burner tFS2: 0 s Controller enable signal delay time tRF: 0 s Minimum burner on time tB: 0 s Safety time during operation tSB: 1 s V2 during burner operation: Off Behavior in the event of flame failure during operation: fault lock-out Burner switch-off threshold: 1 micro A UVS check (1 x in 24 hours): Off Operating time in Manual mode: limited to 5 minutes User-defined password Air monitoring during pre-purge: On Air monitoring during operation: On Gas pressure monitoring: On Digital input function: integrated tightness control TC test period tP: 10 s Fan run-up time tGV: 2 s Valve control: On Bus control activation: On Bus control limitation: ignition position Pre-purge on each start-up: On Pre-purge time tPV: 120 s Post-purge time tPN: 120 s Weight: 1.8 kg Krom schroder BCU370WI1FEU0D3B1-3 88600373 gas burner control unit application Krom schroder 88600373 BCU370WI1FEU0D3B1-3 control box works for both directly ignited forced draught burners and those with pilot burners. It activates the fan and positions the butterfly valve for pre-purge and ignition. After burner startup, it signals an external controller for valve adjustment as needed. Post-purge follows burner shutdown. Kromschroder 88600373 BCU370WI1FEU0D3B1-3 gas burner control box monitors gas and air pressure, with an optional tightness control function for valve monitoring. Programming via optical interface and BCSoft software ensures precise adaptation. Adjustable start-up attempts and automatic restart enhance flexibility. Quick-start allows compliant burner startup without pre-purge, ensuring rapid heat output upon demand.