+370 661-08345تتوفر خدمة الشحن إلى دول الاتحاد الأوروبي
جميع الأسعار لا تشمل ضريبة القيمة المضافةمساعدةتتبع الاستفسار
KROM
Honeywell C7035A1049 كاشف الأشعة فوق البنفسجية «مينيبير»
Honeywell

Honeywell C7035A1049 كاشف الأشعة فوق البنفسجية «مينيبير»

SKU 534.211.030حسب الطلب
‏403.30 €غير شامل ضريبة القيمة المضافة
اطلب عرض السعر
تتوفر خدمة الشحن إلى دول الاتحاد الأوروبي

The Resideo C7035 A 1049 flame detector are designed to detect ultraviolet radiation emitted by a flame. They integrate with Honeywell flame monitoring systems to detect its presence in gas, oil and combined burners. Here are the main characteristics and installation requirements of these detectors: Features - The Honeywell C7035A1049/B UV-sensitive detector are compatible with the R7249A, R7290A, R7749B and R7849A, B amplifiers, as well as with the corresponding Honeywell control devices. - The detectors have a built-in cuff with an internal thread for installation on a one-inch inspection tube. - The housing meets the requirements of Underwriters Laboratories Inc. for protection against moisture and NEMA standards for cabinets of type 4 and 4X. - When properly installed, they can be used at pressures up to 5 psi. - The UV reading tube is replaced in the field. - Parallel connection of two detectors is possible in cases where flame reading is difficult. Specifications - Flame detection: End of flame. - Ambient temperature range: -18°C to +121°C or -40°C to +121°C, depending on the model. - Maximum allowable pressure: 5 psi (34.5 kPa). - Installation: A cuff with an internal thread for installation on a one-inch inspection tube. Electrical connections - Two color-coded wires, NEC Class 1, 6 ft [1.83 m] long (one model comes with 12 ft [3.66 m] long wires). - 1/2-14 NPSM thread for connecting the wire to the rear of the detector. Spare parts 1. Flange seal 129808. 2. UV reading tube 139464M (18° – +121°C). 3. UV reading tube 139464N (18° – +121°C). Basic installation requirements - The detector must be in the direct line of sight of the flame. - Exclude exposure to other sources of ultraviolet radiation, in particular, from ignition sparks. - The detector must be installed as close to the flame as possible, taking into account physical and temperature restrictions. Certification - Underwriters Laboratories Inc.: MP268 certificate. - Canadian Standards Association: Master Report LR 95329-1. - Factory Mutual: certificate. - Industrial Risk Insurers: certificate.

الرموز والإحالات المرجعية

3
Article534.211.030
SKUC7035A1049/U
RefC7035A1049/U, 534.211.030